csd_comet_header_de.jpg - 39606 Bytes
English

T2114 - Barometer with 4-20mA output

barometer

Barometer is equipped with absolute pressure sensor of high accuracy. Transmitter contains a microprocessor based control circuitry in a durable plastic case with connection terminals and sensors. Output range is user adjustable. Display is possible to switch off. Computerized design ensures temperature compensation of the pressure sensor and fail indication. State-of-the-art absolute pressure sensor ensures excellent long term stability.
Display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.

APPLICATIONS - measuring of barometric pressure at:

TECHNICAL PARAMETERS
Maximum measuring range: 600 to 1100hPa
Accuracy: ±(1,3hPa+0.06% from adjusted output span) at 23°C from 800 to 1100hPa
Operating temperature range: -30 to +80°C
Operating temperature range of LCD display: readable to operating temperature +70°C, it is recommended to switch OFF the LCD over +70°C
Range for the output: user adjustable from the PC
Protection: IP54
Power: 9-30Vdc
Dimensions (W x H x D): 89 x 98 x 39,5 mm
Warranty: two years
Type Barometer Description

T2114

barometer - larger photo
Barometric pressure transmitter for outdoor and indoor use.
Display reading and pressure output is user selectable in these units: hPa, kPa, mbar, mmHg, inHg, inH2O, PSI, oz/in2.

Output is adjusted to 800-1100hPa range from the manufacturer.
To adjust other range by the user buying of SP003 cable is necessary - see Optional accessory.
Free configuration program TSensor for transmitter adjustment is ready to download anytime.

If different adjustment of output range is required, please specify required range in the order. Adjustment is free of charge.

Barometer enables to measure sea level pressure by setting of correction to altitude above sea level.

Manual for barometerManual for barometer

barometer wiring

Typical application wiring

Calculation of minimum power voltage Uss for proper operation:
Uss min> Uo min + Imax * Rz,
where: Uo min= 9 V
Imax... approximately 20 mA
Rz... sensing resistor (shunt)

Included accessory:

Traceable calibration certificate from the manufacturer, instruction manual. Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.

Free program TSensor for configuring of the transmitter is ready to download. SP003 cable for barometer adjustment via USB port is necessary to buy.

OPTIONAL ACCESSORY
Larger photo of barometer cable SP003 cable for barometer adjustment via USB port
sensor with connector - larger photo TxxxxL Barometer version with watertight male connector IP67 Lumberg RSFM4 instead of cable gland for easy connection/disconnection of the output.
Specify please your order with letter L behind model code (e.g. TxxxxL)
barometer connector K1427 Female connector ELKA 4012PG7 for TxxxxL transmitters with male connector Lumberg for easy connection/disconnection of the output.
Cable is easily connected to screw terminals of the connector. IP67 protection.
barometer Barometer version with blind lid without LCD.
Specify please the requirement in your order.
Larger photo of barometer Dual Lock MD036 self adhesive Dual Lock for easy installation
Tool for easy transmitter connection - larger photo SP005 Tool for easy wire connection to terminals

data acquisition Barometer is directly compatible with sixteen channel data acquisition system MS.


Declaration of conformity in pdf formatDeclaration of conformity in pdf format