csd_comet_header_de.jpg - 39606 Bytes
English













Optional Accessories for Monitoring systems MS6D, MS6R

Program for data acquisition for monitoring system SWR006 Optional software for Windows - comfort graphic environment data acquisition, including online graph, automatic data download, remote Display mode on Internet-Ethernet network, storing data on the network, administration of users and passwords and many others ..
MS Logger Program DBM Database program DBM MS Logger Program for work with data from Comet MSx loggers.
Program enables i.a.:
- To view selected channels from any Comet logger together with selected channels of other Comet loggers.
- Measurement from different Comet devices is possible to combine in one table or graph.
- To choose any time interval for analysis.
- Print, export to PDF - table and graph.
- Uses popular free database server MySQL.
Optional input for serial RS485 signal - only for data loggers MS6D, MS6R
input RS485IN RS485IN E.g. data acquisition from temperature humidity pressure sensors Tx41x, Hx43x.
Input is designed for reading from devices supporting protocol ModBus RTU or Advantech.
Signal is connected to MS6 terminals right from terminals for channel 15 and 16.
Input can work wit up to 16 devices.
Maximum speed 115200Bd.
Galvanically isolated.
Accessories for data logger mounting
Larger photo of online monitoring system holders MP013 Universal metal wall holders for data logger wall mounting. Package contains a pair of holders and 4 screws.
Larger photo of online monitoring system holder MP012 Holder for data logger mounting to DIN 35mm rail. Package contains the holder and 6 screws.
Larger photo of data logger feet Larger photo of data logger feet MP041 Four rubber feet with screws for desktop use of data logger MS6R.
Only data logger MS6R.
Power supplies
Larger photo of online monitoring system supply A1759 Universal ac/dc adapter 230V-50Hz/21Vdc/1A.
Larger photo of online monitoring system power supply A1940 Universal ac/dc adapter 230V-50Hz/24Vdc/1A/24W for socket plug-in, switch-mode.
Larger photo of online monitoring system power supply A5948 Power supply 230V-50Hz/24Vdc/2,5A for DIN rail 35mm, dual terminals 24Vdc, switch-mode, including DIN rail of 100mm length.
Backup power supplies
Larger photo of online monitoring system power supply A6963
power supply

A7963
battery
Backup power supply A6963, model MINI-DC-UPS/24DC/2 with batery A7963, model MINI-BAT/24DC/1.3AH, manufacturer Phoenix Contact.
Power supply is designed for mounting to 35mm DIN rail in data logger case MP033 and MP034.
It contains two modules - UPS and battery.
Power supply is delivered uninstalled in original manufacturer packaging.
Backup power supply is able to supply data logger system with 200 mA consumption at least 3 hours, data logger system with 500 mA consumption at least 2 hours, data logger system with 1A consumption at least one hour.
Discharged accumulators are recharged to full capacity in approximately 3 hours.
System enables to inform user on switch-over to battery operation.
More details are in Manual Appendixes.
For mounting to MP033 or MP034 case please order: 1pc A6963, 1pc A7963, 1pc MP035 rail.
Larger photo of online monitoring system power supply MP035 DIN rail 35mm of 226mm length with screws for mounting of A6963 power supply with A7963 batery to MP033 or MP034 case.
Larger photo of online monitoring system power supply A6966
power supply

A7966
battery
Backup power supply A6966, model AWZ224, manufacturer Pulsar sp.j., Poland.
To this power supply it is necessary to buy two lead accumulators A7966 12V/7Ah in hermetical maintenance-free type of construction, e.g. type ELNIKA 12V/7.2Ah.
Power supply is designed for mounting to vertical inflammable wall with sufficient air flow. Its protection rate is IP20. It is not designed for mounting to closed switchboard. This backup power supply is able to supply data logger with transmitters of current consumption 200mA for approximately 35 hours. Discharged accumulators are recharged to full capacity in approximately 14 hours.
System enables to inform user on switch-over to battery operation.
More details are in Manual Appendixes.
Please order: 1pc A6966, 2pcs A7966.
Optional internal equipment
monitoring system Ethernet interface MP042 Built-in LAN interface for MS6D, MS6R data logger connection to Ethernet (Internet) network. Communication via: SNMP, SOAP, www pages. In case of limits exceeding alarm is activated and warning e-mail or SNMP trap are sent to specified addresses.
Features of Ethernet interface Monitoring system
External communication converters
Larger photo of online monitoring system converter MP021 Converter RS485/RS232 for serial port COMx at the PC side, including ac/dc adapter and terminator T485.
Larger photo of online monitoring system converter MP022 Converter USB/RS485 for USB port at the PC side, including terminator T485. Powered from computer USB interface.
Larger photo of online monitoring system converter MP023 Converter Ethernet/RS485 including ac/dc adapter and terminator T485. Designed for several data loggers conencted via RS485 network for connection to the computer via Ethernet.
Accessories connectable to ALARM OUT output
Larger photo of data acquisition alarm MP026 External audio indication unit. Enables to signal alarm state acoustically at the location up to 50m from data logger. Audio unit is connected to data logger by a cable (not included).

Note: Audio indication is also built in the external terminals MP016 and MP032.
Output relays module
Larger photo MP018 Output relays module with interconnection cable. It contains 16 mains relays 250V/8A with switching-over contacts. Each relay can be controlled based on alarm creation at different input channels accordingly to setting of user program. Any relay can be assigned to any alarm at any input. Output relays are designed for external devices control (switching of heating, cooling, ventilation, distant alarm etc.). It is necessary to order connection cable to data logger MP017, optionally other accessories.
Larger photo MP017 Connection cable for terminal with display and output relays module - cable length approximately 60cm.
Longer cable lengths available - maximum 2m for relay module, maximum 50m for the terminal with display.
Larger photo of online monitoring system holders MP013 Universal metal wall holders for data logger wall mounting. Package contains a pair of holders and 4 screws.
Larger photo of online monitoring system holder MP019 Holder for relay module mounting to DIN 35mm rail. Package contains the holder and 6 plastic rivets.
Larger photo of online monitoring system holder MP020 DIN rail for relay module with elevated consoles for mounting to the MP033, MP034 case. Rail enables to raise the relay module enables to lead cables to data logger under the module.
Terminals with display
Larger photo of data logger terminal MP016 Terminal with dual line alphanumerical LCD and control buttons, audio alarm indication and 32 alarm LEDs - for panel mounting or mounting to a case lid. Identical functions as built-in terminal of MS5D data logger. It is possible to build in with IP54 protection. Maximum cable length to data logger 50m. It is necessary to order the MP017 connection cable to data logger.
Larger photo MP017 Connection cable for terminal with display and output relays module - cable length approximately 60cm.
Longer cable lengths available - maximum 2m for relay module, maximum 50m for the terminal with display.
MP017-5 Connection cable for terminal with display - cable length 5m.
MP017-10 Connection cable for terminal with display - cable length 10m.
Larger photo of data logger terminal MP032 External terminal with dual line alphanumerical LCD, control buttons, 32 alarm LEDs and audio alarm indication. Built in a IP54 protection case, including 2m cable with covered terminals. Identical functions as built-in terminal of MS5D data logger. Maximum cable length to data logger 50m.
GSM modem and accessories
Data logger modem - larger photo MP009 GSM modem WaveCom Fastrack Supreme, without accessories.
Data logger modem - larger photo MP009/1 Antenna for GSM modem WaveCom Fastrack, right-angled.
Larger photo of online monitoring system cable MP009/2 Communication cable for GSM modem Fastrack.
MP009/3 Ac/dc adapter 230V/12V for GSM modem Fastrack.
Covers, cables and other accessories
Larger photo of data logger cover MP027 Covers of data logger terminals (pair). Designed for aesthetic covering of cables connected to terminals and connectors. Magnetic fixing to data logger.
Larger photo of data logger connector MP030 RS232 connector with terminals for RS232 interface connection by means of terminals, not by D-Sub connector.
Larger photo MP031 Screwdriver for easy connection of cables to WAGO terminals.
Assemblies in case with higher IP protection
Larger photo of online monitoring system case MP033 Case with IP65 protection with wall holders and data logger holders - no cutout in the lid.
Dimensions 270 x 570 x 140 mm.
Connectable sensors and probes
Photo of humidity transmitter Interior temperature, humidity, pressure transmitters Interior temperature, humidity, barometric pressure transmitters
outputs 4-20mA, RS485
Photo of humidity transmitter Industrial temperature, humidity, pressure transmitters Industrial temperature, humidity, barometric pressure transmitters
outputs 4-20mA, RS485
Photo of humidity transmitter Industrial temperature, humidity, pressure transmitters Industrial temperature, humidity, barometric pressure transmitters
serial output RS485
Photo of temperature probe Pt1000
Photo of temperature probe Pt1000
Pt1000 probes temperature probes with Pt1000/3850ppm sensor without connector - probe marking is followed by symbol /0
Photo of thermocouple probe K thermocouple probes temperature probes with K thermocouple NiCr-Ni without connector - probe marking is followed by symbol /0

Data Sheet in pdfData Sheet in pdf
Basic Manual in pdfBasic Manual in pdf
Manual in pdfManual Appendixes in pdf
Declaration of conformity in pdf formatDeclaration of conformity in pdf format

sber dat Back to MS6D, MS6R data loggers page.