Data acquisition system MS55D
NEW - data logger MS55D replaces data loggers MS5D, MS5.
The reason of replacement is to offer system to user, which works from the user point identically as MS6 system, but it is equipped with input modules known from MS5 data loggers.
MS55D data loggers support all advantages of MS6 data loggers including faster communication protocol.
MS55D is designed to applications, where universal inputs of MS6 do not offer required parameters.
The complete solution for monitoring of temperature, humidity and other values especially
in following applications:
- Food and beverages industry (HACCP)
- Pharmaceutical industry (GMP)
- Blood stations, pharmacies
- Horticulture and cultivation of plants
- HVAC (heating, ventilation, air conditioning, cooling
- Building and energy management
- Building automation
- Research and development
- Laboratories (GLP)
Single-channel to sixteen-channel data loggers are designed for recording of values from transducers of variety of quantities, alarm state indication, and process control. Data logger with transducers configured accordingly to client order can measure analog signals, frequency, count impulses, evaluate two-state quantities and read data from devices compatible with Modbus RTU and ADAM Advantech protocol. Input signals are connected to removable terminal block located on the logger upper side. Analyzing of the record is enabled after data download to the personal computer by means of the included program via USB, RS232, Ethernet or GSM modem. Local or remote online data presentation is also enabled.
Free program for monitoring system for Windows is ready to download.
![]() |
MS55D
|

Data acquisition system especially enables:
- online data acquisition by means of the Ethernet interface. Communication via: SNMP, SOAP, internet www pages
- to get information from data logger by means of the SMS messages - actual values, alarms, memory occupation and others - as response to SMS request from the user and after alarm creation at the logger. Data logger should be connected via GSM modem supporting SMS.
- to configure individually each input channel for measurement, alarm evaluation and data logging, including individual data logging interval for each input.
- each input channel can be individually programmed for different modes of record (continuous record, time dependent record, record only if specified logic conditions are matched, record triggered by external signal, etc.).
- to set up to four different logic conditions for each channel to active alarm. Each condition compares measured values from inputs with set limits. It is possible to set hysteresis and delay of condition validity.
- to assign to each input channel name of actual recorded process to identify monitored object (e.g. type of monitored product). It is enabled to select this name from data logger keyboard during the operation.
- to indicate alarm state after matching defined combination up to four alarms from any inputs.
- Input signals are connected by means of the removeable terminal connector. Each input channel has three terminals - including shielding.
TECHNICAL PARAMETERS OF DATA LOGGER | |
---|---|
Memory type: | internal SRAM, backed-up by Lithium battery |
Total memory capacity: | 2MB (up to 480 000 values) |
Data logging modes: |
noncyclic - logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new |
Data logging interval: | adjustable individually for all input channels from 1 second to 24 hours |
Real time clock: | year, leap year, month, day, hour, minute, second, backed-up by Lithium battery |
Input measured values (1 to 16 inputs): | are defined for each channel by installed input modules (see table) accordingly to user requirements |
Resolution of the AD converter (analog channels): | 16 bits, conversion duration approximately 60ms/channel |
Supported interface for communication with computer: |
|
Communication speed: | 9600, 19200, 57600, 115200 Bd, 230400* Bd (* applicable for USB, Ethernet) |
Outputs for alarm indication: |
1) Red LED at the side of the case, 32 LEDs 2) Relay max. 8A/250Vac, switching-over contact 3) Voltage signal 0V/4.8V, maximum current 50mA, output designed for connection of external audio indication unit or telephone voice dialer 4) Alarm can be signalled also by SMS |
Power: | 9 to 30Vdc, 24Vdc recommended |
Operating temperature range: | 0 to +50°C |
Dimensions including connectors: | 215 x 225 x 60 mm |
Protection: | IP20 |
Warranty: | 2 years |
Communication interfaces:
INCLUDED | OPTIONAL | INCLUDED | INCLUDED | INCLUDED |


TYPES OF LOGGER INPUTS Inputs marked with asterisk (*) are available also as galvanically isolated - see notes below table. |
||||
---|---|---|---|---|
Numb. | Type | Measured value | Accuracy | Note |
M1001 | A0 | dc current 4 to 20 mA | ±0.1% FS | With source approximately 21V for two-wire transducers with current loop (e.g. temperature and humidity transducers Comet). Only galvanic not isolated. |
M1002 | A1* | dc current 4 to 20 mA | ±0.1% FS | for passive sensing of current |
M1003 | B0* | dc current 0 to 20mA | ±0.1% FS | |
M1004 | B1* | dc current 0 to 1A | ±0.1% FS | |
M1005 | B2* | dc current 0 to 5A | ±0.1% FS | |
M1006 | C0 | ac current 0 to 20mA | ±1% FS | galvanic isolated only |
M1007 | C1 | ac current 0 to 1A | ±1% FS | galvanic isolated only |
M1008 | C2 | ac current 0 to 5A | ±1% FS | galvanic isolated only |
M1009 | D0* | dc voltage 0 to 100mV | ±0.1% FS | |
M1010 | D1* | dc voltage 0 to 1V | ±0.1% FS | |
M1011 | D2* | dc voltage 0 to 10V | ±0.1% FS | |
M1056 | D5* | dc voltage -10V to +10V |
±0,1% FS (± 20 mV) |
|
M1055 | D4* | dc voltage 0 to 75V | ±0.1% FS | |
M1013 | E0 | ac voltage 0 to 100mV | ±1% FS | galvanic isolated only |
M1014 | E1 | ac voltage 0 to 1V | ±1% FS | galvanic isolated only |
M1015 | E2 | ac voltage 0 to 10V | ±1% FS | galvanic isolated only |
M1059 | E4 | ac voltage 0 to 50V | ±1% FS | galvanically isolated |
M1017 | F* | measurement of resistance (specify the range) | ±0.1% FS | two-wire connection |
M1018 | J* | input for Nickel RTD temperature sensor Ni1000, 6180 ppm/°C, range -50 to +250°C | -50 to 100°C ±0.2°C 100 to 250°C ±0.2% from reading | |
M1019 | K* | input for Platinum RTD temperature sensor Pt100, range -140 to +600°C | -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading | two-wire connection |
M1020 | K1* | input for Platinum RTD temperature sensor Pt1000, range -140 to +600°C | -140 to+100°C ±0.2°C 100 to 600°C ±0.2% from reading | two-wire connection |
M1060 | K3 |
precise input for Platinum RTD temperature sensor Pt1000 range -10 to +50°C |
±0.06°C |
Two-wire connection. Only galvanically not isolated. |
M1021 | N* | thermocouple K (NiCr-Ni) range -70 to +1300°C | ±0.3% from reading + 1.5°C | linearized, cold junction compensation |
M1054 | T* | thermocouple T (Cu-CuNi) range -200 to +400°C | ±0.3% from reading + 1.5°C | linearized, cold junction compensation |
M1022 | O* | thermocouple J (Fe-Co) range -200 to 750°C | ±0.3% from reading + 1.5°C | linearized, cold junction compensation |
M1023 | P* | thermocouple S (Pt10%Rh-Pt), range 0 to 1700°C | ±0.3% from reading + 1.5°C from +200 to +1700°C | linearized, cold junction compensation |
M1024 | Q* | thermocouple B (Pt30%Rh-Pt), range +100 to +1800°C | ±0.3% from reading + 1.0°C from +300 to +1800°C | linearized, without cold junction compensation |
M1041 | S* | binary input for potential-less contacts | maximum resistance of closed contact: 1000 ohms minimum duration for recording: 200ms |
M1042 | S1 | binary voltage input | voltage for "switched ON" state: 3 to 30Vdc, input current in the"switched ON" state: 1 to 9mA-depending on the applied voltage, minimum duration for indication of change: 200ms, galvanic isolated |
M1044 | CTU | counter input for voltage signal | voltage for "HIGH" state (for counter status change): 3 to 24Vdc maximum pulse frequency 5kHz, backed-up operation, galvanic isolated |
M1045 | CTK | counter input for potential-less contacts and open collector | maximum pulse frequency 5kHz, programmable filter of pulse ringing, backed-up operation during power mains failure, maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, galvanic unisolated |
M1047 | FU | input for measurement of frequency of voltage signal | 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) input voltage for state "H": 3 to 24Vdc input current in state "H": approximately 7mA minimum duration of input impuls: 30us, galvanic isolated |
M1048 | FK | input for measurement of frequency of contact switching | 0 to 5kHz, resolution 1Hz, accuracy ±(0.2% from reading + 1Hz) maximum resistance of closed contact: 10 kohms minimum resistance of open contact: 250 kohms, minimum duration of input pulse: 30us, galvanic unisolated |
M1061 | RP | input for serial signal RS485 for devices supporting Modbus RTU or Advantech protocol |
E.g. measurement from Comet Tx41x temperature, humidity, pressure, transmitters. Only devices using same communication protocol and same communication speed can be connected to one RP module. Maximum speed 115200Bd. Galvanic isolated. Not compatible with older models MS234+. |
Inputs marked ( * ) are not galvanic isolated and have common ground.
These inputs are available also as galvanic isolated.
Galvanic isolated analog inputs are marked with letter G following the name of input type (e.g. input for passive measurement of current 4-20mA - type A1 - with galvanic isolation is marked A1G).
Galvanic isolation is not designed as safety protection.
Input module A0 4-20mA
Counter input module CTU
Included Accessories:
Traceable calibration certificate from the manufacturer with declared metrological ethalon traceability in accordance with EN ISO/IEC 17025.Example of calibration certificate.
Included is also RS232 communication cable of 2 meters length, USB communication cable A-B of 1.8 meters length and free program for Windows.
Free program is available to dowload anytime. Program enables to control all logger functions and view and print the record in numerical format. It is possible to export recorded data to dbf formats for further analysis, e.g. in MS Excel.
For work with graphs and other functions is possible to order optional program SWR006 or database program DBM MS Logger Program - see Optional Accessories.