Temperature, Humidity, Regulators with Relay Outputs
Humidistat H3060, H3020
- temperature
- relative humidity
- dew point temperature
- absolute humidity
- specific humidity
- mixing ratio
- specific enthalpy
Humidistats are designed for two-state control of e.g. heating, ventilation, humidifier, dehumidifier, etc.
Transmitter is equipped with two relay outputs for alarm indication or control of external devices. Each relay can be assigned to any measured or computed value.
For each relay setting of delay, hysteresis, audible alarm is enabled.
Measured temperature and relative humidity is recalculated to other humidity interpretations - dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy.
Parameters are easy adjustable from regulator keyboard or from the computer.
Large dual line LCD for simultaneous display of temperature, relative humidity or other calculated humidity interpretation is an advantage.
State-of-the-art capacitive polymer sensor ensures excellent calibration long term stability, inertia against water and condensation. Transmitter is designed for use in non-aggressive environment.
Models H3061P and H3021P are designed for compressed air measurement up to 25 bars.
HUMIDISTAT APPLICATIONS
- temperature and humidity control- monitoring of temperature, humidity:
- building management and automation
- server rooms
- telecommunication devices
- warehouses, glasshouses
- manufacturers
- museums, archives, galleries
- air-conditioned rooms, HVAC
- weather stations
COMMON TECHNICAL PARAMETERS | |
---|---|
Maximum switching voltage, current of relay output - models H3060, H3061: |
250Vac, 8A
New ! |
Maximum switching voltage, current of relay output - models H3020, H3021, H3023: |
50V, 2A, 60VA |
Audible alarm: | from built-in beeper - switchable |
Supported temperature units: | degrees Celsius, degrees Fahrenheit |
Accuracy of temperature measurement: | ±0.4°C from -30 to +100°C, ±0.4% from reading over +100°C |
Range of relative humidity measurement: | 0 to 100% |
Accuracy of relative humidity measurement: | ±2.5% relative humidity from 5 to 95% at 23°C |
Accuracy of temperature measurement: |
±0.4°C from -30 to +100°C ±0.4% from reading over +100°C |
Accuracy and measuring range of dew-point temperature: - for more details see graphs |
±1,5 °C at ambient temperature T < 25°C and RH>30% range -60 to +80 °C |
Accuracy and measuring range of absolute humidity: | ±3g/m3 at ambient temperature T < 40°C range 0 to 400 g/m3 |
Accuracy and measuring range of specific humidity: | ±2g/kg at ambient temperature T < 35°C range 0 to 550 g/kg |
Accuracy and measuring range of mixing ratio: | ±2g/kg at ambient temperature T < 35°C range 0 to 995 g/kg |
Accuracy and measuring range of specific enthalpy: | ± 3kJ/kg at ambient temperature T < 25°C range: 0 to 995 kJ/kg |
Operating temperature range of the case with electronics: | -30 to +80°C |
Operating temperature range of LCD display: | readable up to operating temperature +70°C, it is recommended to switch off LCD over +70°C |
Range of temperature compensation of RH sensor: | -30 to +125°C |
Filtering ability of sensor cover: | 0.025mm - filter from stainless steel mesh |
Protection: |
IP65 electronics with terminals, IP40 humidity and temperature sensors |
Power - models H3060, H3061: |
110 to 240V / 50Hz to 60Hz New ! |
Power - models H3020, H3021, H3023: |
9-30Vdc |
Dimensions of the case: | 135 x 136 x 45 mm (W x H x D) |
Warranty: | 2 years |
Humidistats are available in the following models:
To set regulator easily by the user from the PC program buying of SP003 cable is necessary - see Optional accessory.
Free configuration program TSensor for regulator adjustment is ready to download anytime.
It is also enabled to adjust regulator from the instrument keyboard.
If different adjustment of relay outputs is required, please specify required output values (RH, T, Tdp, ..) in the order. Adjustment is free of charge.
Any measured value - temperature, relative humidity, dew point temperature, absolute humidity, specific humidity, mixing ratio or specific enthalpy can be assigned to each output of dual output transmitters.
Also identical value can be assigned to both outputs.
* Relative humidity at temperature over +85°C is limited in accordance with the graph. Near plastic case with electronics and probe cable maximum temperature is +80°C.
Figure: Humidistat working range
Figure:
H3061P, H3021P humidity probe for compressed air up to 25 bars
- hard anodized duralumin, stainless steel mesh filter moulded in polycarbonate
Figure: Flow chamber SH-PP for compressed air measurement up to 25 bars - stainless steel
Included accessories:
Traceable calibration certificate from the manufacturer, instruction manual.
Calibration certificate with declared metrological traceability of etalons is based on requirements of EN ISO/IEC 17025 standard.
Example of calibration certificate.
Free program TSensor for configuring of the transmitter is ready to download. SP003 cable for barometer adjustment via USB port is necessary to buy.
HUMIDISTAT OPTIONAL ACCESSORY | ||
---|---|---|
SP003 | cable for humidity regulator adjustment via USB port | |
F5200 | grey sensor cover with filter from stainless steel mesh, filtering ability 0,025mm | |
F5200B | black sensor cover with filter from stainless steel mesh, filtering ability 0,025mm | |
F0000 | sintered bronze sensor cover. Filtering ability 0.025mm. | |
PP4 | flat plastic circular flange for duct mounting | |
PP90 | right-angled stain-less steel flange for wall mounting | |
SP004 | plastic gland for direct mounting of the humidity probe to a 29 mm diameter hole | |
MD036 | self adhesive Dual Lock for easy installation | |
SP006 | Tool for easy wire connection to terminals | |
A1510 | ac/dc adapter 230V-50Hz/12Vdc | |
F8000 | Solar radiation shield for transmitters H3061, H3021 with T+RH probe on a cable | |
SH-PP |
Flow chamber for compressed air measurement up to 25 bars - stainless steel DIN 1.4301
inlet and outlet connection - G1/8 thread humidity probe connection - G1/2 thread screw-coupling not included |
|
accessory for calibration and adjustment of humidity by the user |
Ethernet temperature, humidity, pressure sensors | Low cost temperature, humidity, pressure sensors |
Transmitters with 4-20mA and RS485 outputs are directly compatible with sixteen channel Comet data acquisition system MS.
Declaration of conformity in pdf format for humidistats H306x
Declaration of conformity in pdf format for humidistats H302x